{"product_id":"deckenkassette-fujitsu-eco-auxg09kvla-aoeg09kata-2-5-kw","title":"Fujitsu Eco AUXG09KVLA Ceiling Cassette 2.5 kW","description":"\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003e\u003cstrong\u003eThe Fujitsu Eco AUXG09KVLA is a 4-way split ceiling cassette with a cooling capacity of 2.5 kW and a heating capacity of 3.2 kW, consisting of the AUXG09KVLA indoor unit with UTG-UFYF-W grille and the AOEG09KATA outdoor unit.\u003c\/strong\u003e SEER 6.2 and SCOP 4.0, energy efficiency class A++ for cooling and A+ for heating according to page A on the A+++ to D scale. According to page 6, the grille measures 620 x 620 mm and fits into a ceiling grid system of this size; the condensate pump is standard according to page 6. As a guideline, the power class is suitable for rooms of approximately 19 to 25 m²\u003csup\u003e*\u003c\/sup\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003ePerformance and range of application\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe cooling capacity is 2.5 kW (adjustable range 0.9 to 2.7 kW), the heating capacity 3.2 kW (adjustable range 0.9 to 3.9 kW). According to the table, the unit operates at outdoor temperatures from minus 15 to plus 46 °C in cooling mode and from minus 15 to plus 24 °C in heating mode, single-phase at 230 V. The page does not state the power consumption and annual consumption; we will provide the energy label upon request.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe stated area of approximately 19 to 25 m²\u003csup\u003e*\u003c\/sup\u003e is a guideline for standard room height and normal insulation standards, not a binding design. Which power class is right for your property depends on room height, insulation standards, window areas, shading, as well as the number of people and devices. We will check the appropriate design for your property upon request.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 1.4em;line-height:1.6;font-size:0.88em;color:#555555;\"\u003e* Guideline based on the cooling capacity specified by the manufacturer, at a standard room height of approximately 2.5 m, normal insulation standards and average solar radiation. Different conditions on site, such as large window areas, sloped roofs or a high number of people, may require a different power class. The binding design is carried out on a property-specific basis. For a professional design of your property \u003ca href=\"https:\/\/warmandcold-shop.de\/pages\/kontakt\" target=\"_blank\" rel=\"noopener\"\u003eplease contact us\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eThe most important advantages at a glance\u003c\/h2\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003e2.5 kW cooling and 3.2 kW heating capacity\u003c\/strong\u003e, adjustable range 0.9 to 2.7 kW and 0.9 to 3.9 kW respectively according to the table.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eEnergy efficiency class A++ in cooling and A+ in heating\u003c\/strong\u003e according to the page, A+++ to D scale, with SEER 6.2 and SCOP 4.0.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eUTG-UFYF-W grille included\u003c\/strong\u003e, 620 x 620 mm for the ceiling grid system according to page 6.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eCondensate pump standard\u003c\/strong\u003e according to page 6.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eIndoor unit from 27 dB(A)\u003c\/strong\u003e on the lowest setting in cooling mode according to the table.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eWeekly timer, night program and external control input\u003c\/strong\u003e; MODBUS and KNX connection optional according to page 6.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eDetailed functions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eInverter and heat pump operation\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe inverter adjusts the power to the demand: between 0.9 and 2.7 kW in cooling mode, between 0.9 and 3.9 kW in heating mode. In heating mode, the unit operates as an air-to-air heat pump and uses the outdoor air down to minus 15 °C according to the table. The 10-degree function keeps the room at 10 °C when unoccupied according to page 6, the automatic mode change switches between cooling and heating depending on the room temperature according to page 6. Seasonal values according to the table: SEER 6.2, SCOP 4.0.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eAirflow and filter\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe louvers swing up and down automatically according to page 6, the air volume adjusts automatically according to page 6. The air inlet grille can be rotated in any direction according to page 6, which facilitates filter access during maintenance; an LED indicates when the filter needs to be cleaned according to page 6. The page does not provide information on filter performance.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eOperating modes\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eCooling: 2.5 kW nominal, range 0.9 to 2.7 kW\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eHeating: 3.2 kW nominal, range 0.9 to 3.9 kW, down to minus 15 °C according to the table\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAutomatic mode change between cooling and heating according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eEnergy-saving mode with limited setpoint range and temperature reset according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e10-degree function for frost protection when unoccupied according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eNight program with gradual adjustment of the room temperature according to page 6\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eControl and comfort\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eRemote control included; weekly timer and programmer with four switching cycles according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eExternal control input and automatic shut-off according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eConnection to MODBUS and KNX interfaces optional according to page 6, accessories available upon request\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eOperational safety\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAutomatic restart after power failure according to page 6\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eOperating range according to the table: minus 15 to plus 46 °C cooling, minus 15 to plus 24 °C heating\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eCondensate pump standard according to page 6; the page does not state the delivery head\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eScope of delivery\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eIncluded in the standard scope:\u003c\/p\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x Fujitsu AUXG09KVLA indoor unit with UTG-UFYF-W grille\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x Fujitsu AOEG09KATA outdoor unit\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x remote control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat you need additionally\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eRefrigerant lines 6.35 mm + 9.52 mm; maximum line length according to the table 15 m\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eCondensate line and mounting material for ceiling mounting\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eWall bracket or floor console for the outdoor unit (23 kg)\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eElectrical supply line and circuit breaker\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eInstallation and commissioning by a specialist company\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eTechnical data\u003c\/h2\u003e\n\n\u003ctable style=\"margin:0.5em 0 1.5em;border-collapse:collapse;width:100%;\"\u003e\n\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIndoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu AUXG09KVLA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eGrille\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eUTG-UFYF-W, 620 x 620 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu AOEG09KATA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kW (0.9 to 2.7 kW)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3.2 kW (0.9 to 3.9 kW)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy efficiency class cooling \/ heating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eA++ \/ A+ according to page A, A+++ to D scale\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSEER \/ SCOP according to the table\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6.2 \/ 4.0\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower consumption, annual consumption\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003esingle-phase, 230 V, 50 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level indoor unit cooling (four settings)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e33 \/ 31 \/ 29 \/ 27 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level indoor unit heating (four settings)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e34 \/ 32 \/ 29 \/ 27 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level outdoor unit cooling \/ heating (high)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e47 \/ 48 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions indoor unit (H x W x D), weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e245 x 570 x 570 mm, 15 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions grille (H x W x D), weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e49 x 620 x 620 mm, 2.3 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions outdoor unit (H x W x D), weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e541 x 663 x 290 mm, 23 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePipe connections liquid + gas\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e6.35 mm + 9.52 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. line length according to the table\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHeight difference\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating range outdoor temperature cooling \/ heating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eminus 15 to plus 46 °C \/ minus 15 to plus 24 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCondensate pump\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003estandard according to page 6\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ EU representative according to page 6\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu General Euro GmbH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat cooling and heating capacity does the Fujitsu Eco AUXG09KVLA with 2.5 kW have?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, 2.5 kW in cooling and 3.2 kW in heating, with adjustable ranges of 0.9 to 2.7 kW and 0.9 to 3.9 kW. SEER 6.2 and SCOP 4.0 according to the table, energy efficiency class A++ in cooling and A+ in heating according to page A on the A+++ to D scale. We will check which power class is right for your room upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat ceiling opening and installation height does the cassette need?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, the indoor unit measures 245 x 570 x 570 mm (height x width x depth) and weighs 15 kg, the grille 49 x 620 x 620 mm at 2.3 kg. According to page 6, the grille fits into a ceiling grid system with 620 x 620 mm; the cavity must accommodate the unit height of 245 mm including lines. We will provide the installation instructions upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat exactly is included in the scope of delivery?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe delivery includes exclusively the AUXG09KVLA indoor unit with the UTG-UFYF-W grille, the AOEG09KATA outdoor unit and a remote control. Refrigerant lines, condensate line, bracket for the outdoor unit and mounting material are not included; this page does not offer a mounting set. We will state suitable material upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eDoes the cassette have a condensate pump?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eYes. According to page 6, the condensate pump is built in as standard; the page does not state the delivery head, we will provide it upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow long can the line between the indoor and outdoor unit be?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, the maximum line length is 15 m. The pipe connections are stated as 6.35 mm + 9.52 mm, the page does not state the maximum height difference. We will check which line route is permissible for your property and whether the system needs to be supplemented by a specialist company upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I use the unit for heating in winter?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eYes. According to the table, the heating mode is stated down to minus 15 °C outdoor temperature; the heating capacity is 3.2 kW, at maximum 3.9 kW, energy efficiency class in heating according to page A+ on the A+++ to D scale, SCOP 4.0. The available power decreases with falling outdoor temperature, which is why the system is suitable as a supplement to the existing heating system.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow loud is the unit?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eFor the indoor unit, the table states 33 \/ 31 \/ 29 \/ 27 dB(A) in cooling and 34 \/ 32 \/ 29 \/ 27 dB(A) in heating, each on four settings. The outdoor unit is stated with 47 \/ 48 dB(A) in cooling and heating on the high setting.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I install the air conditioner myself?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe installation and commissioning of a split air conditioner is carried out by a certified specialist company. Self-installation is not intended.\u003c\/p\u003e\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Welche Kühl- und Heizleistung hat die Fujitsu Eco AUXG09KVLA mit 2,5 kW?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laut Tabelle 2,5 kW im Kühlen und 3,2 kW im Heizen, mit Regelbereichen von 0,9 bis 2,7 kW und 0,9 bis 3,9 kW. SEER 6,2 und SCOP 4,0 laut Tabelle, Energieeffizienzklasse laut Seite A++ im Kühlen und A+ im Heizen auf der Skala von A+++ bis D. Welche Leistungsklasse für Ihren Raum passt, prüfen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Welche Deckenöffnung und welche Einbauhöhe braucht die Kassette?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Das Innengerät misst laut Tabelle 245 x 570 x 570 mm (Höhe x Breite x Tiefe) und wiegt 15 kg, die Blende 49 x 620 x 620 mm bei 2,3 kg. Laut Seite passt die Blende in ein Rasterdeckensystem mit 620 x 620 mm; der Hohlraum muss die Gerätehöhe von 245 mm samt Leitungen aufnehmen. Die Installationsanleitung geben wir auf Anfrage weiter.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Was genau ist im Lieferumfang enthalten?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Die Lieferung umfasst ausschließlich das Innengerät AUXG09KVLA mit der Blende UTG-UFYF-W, das Außengerät AOEG09KATA und eine Fernbedienung. Kältemittelleitungen, Kondensatleitung, Halterung für das Außengerät und Montagematerial sind nicht enthalten; ein Montageset bietet diese Seite nicht an. Passendes Material nennen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Hat die Kassette eine Kondensatpumpe?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ja. Die Kondensatpumpe ist laut Seite serienmäßig eingebaut; die Förderhöhe nennt die Seite nicht, wir reichen sie auf Anfrage nach.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie lang darf die Leitung zwischen Innen- und Außengerät sein?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laut Tabelle beträgt die maximale Leitungslänge 15 m. Die Rohranschlüsse sind mit 6,35 mm + 9,52 mm angegeben, die maximale Höhendifferenz nennt die Seite nicht. Welcher Leitungsweg für Ihr Objekt zulässig ist und ob die Anlage dafür vom Fachbetrieb ergänzt werden muss, prüfen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Kann ich mit dem Gerät im Winter heizen?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ja. Der Heizbetrieb ist laut Tabelle bis minus 15 °C Außentemperatur angegeben; die Heizleistung beträgt 3,2 kW, im Maximum 3,9 kW, Energieeffizienzklasse im Heizen laut Seite A+ auf der Skala von A+++ bis D, SCOP 4,0. Die verfügbare Leistung sinkt mit fallender Außentemperatur, weshalb sich die Anlage als Ergänzung zur vorhandenen Heizung eignet.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie laut ist das Gerät?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Für das Innengerät nennt die Tabelle 33 \/ 31 \/ 29 \/ 27 dB(A) im Kühlen und 34 \/ 32 \/ 29 \/ 27 dB(A) im Heizen, jeweils auf vier Stufen. Das Außengerät ist mit 47 \/ 48 dB(A) im Kühlen und Heizen auf der hohen Stufe angegeben.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Darf ich die Klimaanlage selbst montieren?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Die Installation und Inbetriebnahme einer Split-Klimaanlage übernimmt ein zertifizierter Fachbetrieb. Eine Selbstmontage ist nicht vorgesehen.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":52981947924747,"sku":null,"price":1799.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0488\/7029\/3656\/files\/FujitsuAUXG09KVLA.png?v=1773909671","url":"https:\/\/warmandcold-shop.de\/en\/products\/deckenkassette-fujitsu-eco-auxg09kvla-aoeg09kata-2-5-kw","provider":"warm\u0026cold","version":"1.0","type":"link"}