{"product_id":"deckenklimaanlage-fujitsu-abeg54krta-aoeg54krta-13-4-kw","title":"Fujitsu ABEG54KRTA Ceiling-Mounted Air Conditioner 13.4 kW","description":"\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003e\u003cstrong\u003eThe Fujitsu ABEG54KRTA cools at 13.4 kW and heats at 15.5 kW nominal capacity; the ABEG54KRTA indoor unit is mounted as a ceiling-suspended unit below the ceiling, while the AOEG54KRTA outdoor unit operates outside.\u003c\/strong\u003e SEER 5.88 and SCOP 3.95, but the page does not state an energy efficiency class. According to the table, the indoor unit is 235 mm high; a wired remote control is included, and the page states that the drain hose can be routed to the right, left, side, or downwards beneath the unit. As a guide, the power class is suitable for rooms of approximately 103 to 134 m²\u003csup\u003e*\u003c\/sup\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003ePerformance and range of application\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe cooling capacity is 13.4 kW (adjustable range 4.5 to 14.5 kW), and the heating capacity is 15.5 kW (adjustable range 4.7 to 16.5 kW). According to the table, the unit operates in cooling mode at outdoor temperatures from minus 15 to plus 46 °C and in heating mode from minus 15 to plus 24 °C, three-phase at 400 V. The page does not state the power consumption or annual consumption; we can provide the energy label upon request.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe stated area of approximately 103 to 134 m²\u003csup\u003e*\u003c\/sup\u003e is a guideline based on standard room height and normal insulation standards, not a binding design. For shops, offices, and dining areas, additional internal loads from people, lighting, and equipment may increase the requirements compared to the guideline. We can check the appropriate design for your property upon request.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 1.4em;line-height:1.6;font-size:0.88em;color:#555555;\"\u003e* Guideline based on the cooling capacity specified by the manufacturer, at a standard room height of approximately 2.5 m, normal insulation standards, and average solar radiation. Different conditions on site, such as large window areas, sloped roofs, or a high number of people, may require a different power class. The binding design is carried out on a property-specific basis. For a professional design of your property, \u003ca href=\"https:\/\/warmandcold-shop.de\/pages\/kontakt\" target=\"_blank\" rel=\"noopener\"\u003eplease contact us\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eThe most important advantages at a glance\u003c\/h2\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003e13.4 kW cooling and 15.5 kW heating capacity\u003c\/strong\u003e, adjustable range 4.5 to 14.5 kW and 4.7 to 16.5 kW respectively, according to the table.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eSEER 5.88 and SCOP 3.95\u003c\/strong\u003e according to the table; the page does not state an energy efficiency class.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eWired remote control included\u003c\/strong\u003e, weekly timer and external control input according to the page.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eIndoor unit 235 mm high\u003c\/strong\u003e, 235 x 1,700 x 705 mm, for mounting below the ceiling.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eIndoor unit from 38 dB(A)\u003c\/strong\u003e on the lowest setting according to the table.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eFresh air supply via duct\u003c\/strong\u003e with optional module; MODBUS and KNX connection optional according to the page.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eDetailed functions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eInverter and heat pump operation\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe inverter control maintains the capacity between 4.5 and 14.5 kW in cooling and 4.7 and 16.5 kW in heating; as an air-to-air heat pump, the unit heats down to minus 15 °C outdoor temperature according to the table. The automatic mode change switches between cooling and heating depending on the setpoint temperature and room temperature according to the page; the energy-saving mode limits the adjustable temperature range according to the page. Seasonal values according to the table: SEER 5.88, SCOP 3.95.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eAirflow and filters\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the page, the louvers swing up and down automatically, and the airflow adjusts automatically. The front panel can be opened without disassembly and removed for cleaning according to the page; an LED indicates when the filter needs cleaning according to the page. According to the page, outdoor air can be supplied via ducts and an optional module. The page does not provide information on filter efficiency.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eOperating modes\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eCooling: 13.4 kW nominal, range 4.5 to 14.5 kW\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eHeating: 15.5 kW nominal, range 4.7 to 16.5 kW, down to minus 15 °C according to the table\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAutomatic mode change between cooling and heating according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eEnergy-saving mode with limited setpoint range and temperature reset according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eFresh air supply via duct with optional module according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAutomatic shut-off and weekly timer according to the page\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eControl and comfort\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eWired remote control included; weekly timer according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eExternal control input and automatic shut-off according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eConnection to MODBUS and KNX interfaces optional according to the page, accessories available upon request\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eOperational safety\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAutomatic restart after power failure according to the page\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eOperating range according to the table: minus 15 to plus 46 °C cooling, minus 15 to plus 24 °C heating\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eAccording to the page, the drain hose and pipes can be routed to the right, left, side, or downwards beneath the unit; the page does not state a condensate pump\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eBlue Fins: evaporator corrosion protection according to the page\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eScope of delivery\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eIncluded in the standard scope:\u003c\/p\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x Fujitsu ABEG54KRTA indoor unit\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x Fujitsu AOEG54KRTA outdoor unit\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e1x wired remote control\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat you need additionally\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eRefrigerant lines 9.52 mm + 15.88 mm; maximum line length according to the table 50 m\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eCondensate line and mounting material for ceiling mounting\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eWall bracket or floor console for the outdoor unit (67 kg)\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eElectrical supply line and circuit protection\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eInstallation and commissioning by a certified company\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eTechnical data\u003c\/h2\u003e\n\n\u003ctable style=\"margin:0.5em 0 1.5em;border-collapse:collapse;width:100%;\"\u003e\n\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eIndoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu ABEG54KRTA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOutdoor unit\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu AOEG54KRTA\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal cooling capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e13.4 kW (4.5 to 14.5 kW)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNominal heating capacity (range)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e15.5 kW (4.7 to 16.5 kW)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy efficiency class cooling \/ heating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSEER \/ SCOP according to the table\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e5.88 \/ 3.95\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower consumption, annual consumption\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ethree-phase, 400 V, 50 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level indoor unit cooling (four settings)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e48 \/ 44 \/ 41 \/ 38 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level indoor unit heating (four settings)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e48 \/ 44 \/ 41 \/ 38 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level outdoor unit cooling \/ heating (high)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e57 \/ 59 dB(A)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions indoor unit (H x W x D), weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e235 x 1,700 x 705 mm, 38 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions outdoor unit (H x W x D), weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e998 x 940 x 320 mm, 67 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePipe connections liquid + gas\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e9.52 mm + 15.88 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. line length according to the table\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50 m\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHeight difference\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating range outdoor temperature cooling \/ heating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eminus 15 to plus 46 °C \/ minus 15 to plus 24 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eCondensate pump\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page; drain hose freely routable according to the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBlue Fins\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eevaporator corrosion protection according to the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eManufacturer \/ EU representative according to the page\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFujitsu General Euro GmbH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat cooling and heating capacity does the Fujitsu ABEG54KRTA with 13.4 kW have?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, 13.4 kW in cooling and 15.5 kW in heating, with adjustable ranges of 4.5 to 14.5 kW and 4.7 to 16.5 kW. SEER 5.88 and SCOP 3.95 according to the table; the page does not state an energy efficiency class. We can check which power class is suitable for your room upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow big is the indoor unit and how is it mounted?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, the indoor unit measures 235 x 1,700 x 705 mm (height x width x depth) and weighs 38 kg; it hangs visibly below the ceiling and does not require a ceiling void. The drain hose and pipes can be routed to the right, left, side, or downwards beneath the unit according to the page; the outdoor unit AOEG54KRTA measures 998 x 940 x 320 mm and weighs 67 kg.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat exactly is included in the scope of delivery?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe delivery exclusively includes the ABEG54KRTA indoor unit, the AOEG54KRTA outdoor unit, and a wired remote control. Lines, condensate line, bracket, and mounting material must be ordered separately; a mounting set is not selectable on this page. We can provide suitable material upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eDoes the unit have a condensate pump?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe page does not state a condensate pump. According to the page, the drain hose can be routed to the right, left, side, or downwards beneath the unit, so that the condensate can be drained with a slope; we can clarify upon request whether a pump is available as an accessory.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow long can the line between the indoor and outdoor unit be?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the table, the maximum line length is 50 m. The pipe connections are stated as 9.52 mm + 15.88 mm, the page does not state the maximum height difference. We can check upon request which line route is permissible for your property and whether the system needs to be supplemented by a certified company.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I use the unit for heating in winter?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eYes. According to the table, the heating mode is specified down to minus 15 °C outdoor temperature; the heating capacity is 15.5 kW, at maximum 16.5 kW, the energy efficiency class in heating according to the page is not stated. At low outdoor temperatures, the available heating capacity decreases, so the system supplements the existing heating and does not replace it.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow loud is the unit?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eFor the indoor unit, the table states 48 \/ 44 \/ 41 \/ 38 dB(A) in cooling and 48 \/ 44 \/ 41 \/ 38 dB(A) in heating, each on four settings. The outdoor unit is stated at 57 \/ 59 dB(A) in cooling and heating on the high setting.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I install the air conditioner myself?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe installation and commissioning of a split air conditioner is carried out by a certified company. Self-installation is not intended.\u003c\/p\u003e\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Welche Kühl- und Heizleistung hat die Fujitsu ABEG54KRTA mit 13,4 kW?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laut Tabelle 13,4 kW im Kühlen und 15,5 kW im Heizen, mit Regelbereichen von 4,5 bis 14,5 kW und 4,7 bis 16,5 kW. SEER 5,88 und SCOP 3,95 laut Tabelle, eine Energieeffizienzklasse nennt die Seite nicht. Welche Leistungsklasse für Ihren Raum passt, prüfen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie groß ist das Innengerät und wie wird es montiert?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Das Innengerät misst laut Tabelle 235 x 1.700 x 705 mm (Höhe x Breite x Tiefe) und wiegt 38 kg; es hängt sichtbar unter der Decke und braucht keinen Deckenhohlraum. Ablaufschlauch und Rohrleitungen lassen sich laut Seite unter dem Gehäuse nach rechts, links, zur Seite oder nach unten führen; das Außengerät AOEG54KRTA misst 998 x 940 x 320 mm und wiegt 67 kg.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Was genau ist im Lieferumfang enthalten?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Die Lieferung umfasst ausschließlich das Innengerät ABEG54KRTA, das Außengerät AOEG54KRTA und eine Kabelfernbedienung. Leitungen, Kondensatleitung, Halterung und Montagematerial müssen gesondert bestellt werden; ein Montageset ist auf dieser Seite nicht wählbar. Wir nennen Ihnen passendes Material auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Hat das Gerät eine Kondensatpumpe?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Eine Kondensatpumpe nennt die Seite nicht. Der Ablaufschlauch lässt sich laut Seite unter dem Gehäuse nach rechts, links, zur Seite oder nach unten verlegen, sodass das Kondensat mit Gefälle abgeführt werden kann; ob eine Pumpe als Zubehör erhältlich ist, klären wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie lang darf die Leitung zwischen Innen- und Außengerät sein?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laut Tabelle beträgt die maximale Leitungslänge 50 m. Die Rohranschlüsse sind mit 9,52 mm + 15,88 mm angegeben, die maximale Höhendifferenz nennt die Seite nicht. Welcher Leitungsweg für Ihr Objekt zulässig ist und ob die Anlage dafür vom Fachbetrieb ergänzt werden muss, prüfen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Kann ich mit dem Gerät im Winter heizen?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ja. Der Heizbetrieb ist laut Tabelle bis minus 15 °C Außentemperatur angegeben; die Heizleistung beträgt 15,5 kW, im Maximum 16,5 kW, Energieeffizienzklasse im Heizen laut Seite nennt die Seite nicht. Bei tiefen Außentemperaturen sinkt die verfügbare Heizleistung, sodass die Anlage die vorhandene Heizung ergänzt und nicht ersetzt.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie laut ist das Gerät?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Für das Innengerät nennt die Tabelle 48 \/ 44 \/ 41 \/ 38 dB(A) im Kühlen und 48 \/ 44 \/ 41 \/ 38 dB(A) im Heizen, jeweils auf vier Stufen. Das Außengerät ist mit 57 \/ 59 dB(A) im Kühlen und Heizen auf der hohen Stufe angegeben.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Darf ich die Klimaanlage selbst montieren?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Die Installation und Inbetriebnahme einer Split-Klimaanlage übernimmt ein zertifizierter Fachbetrieb. Eine Selbstmontage ist nicht vorgesehen.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":52981895299339,"sku":null,"price":5199.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0488\/7029\/3656\/files\/ABEG36KRTA.png?v=1773842301","url":"https:\/\/warmandcold-shop.de\/en\/products\/deckenklimaanlage-fujitsu-abeg54krta-aoeg54krta-13-4-kw","provider":"warm\u0026cold","version":"1.0","type":"link"}