{"product_id":"trinnity-hd-lufterhitzer-24-5-bis-70-kw-hallenheizung","title":"Trinnity HD Air Heater 24.5 to 70 kW","description":"\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003e\u003cstrong\u003eTrinnity HD: water-air heater for halls, workshops and warehouses, supplied with heating water from a boiler, heat pump or district heating; the fan distributes the air heated at the heat exchanger throughout the room.\u003c\/strong\u003e On this page, you can choose between 4 sizes (HD25, HD40, HD50, HD70) with heating capacities of 24.5 to 70.0 kW according to the page\u003csup\u003e*\u003c\/sup\u003e and accessories as required (with swivel bracket and 3-speed controller with CTS thermostat, with swivel bracket and programmable CHMI control, complete set). Connected to 230 V, AC motor according to the page; three fan speeds (AC fan).\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003ePerformance and range of application\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eHeating capacity according to the page: HD25 24.5 kW; HD40 37.8 kW; HD50 48.5 kW; HD70 70.0 kW. Nominal values according to the page without specification of the water and air temperatures; the technical data is provided on the page exclusively as an image. For a water-air heater, the heating water determines the performance: a high flow temperature from the boiler achieves the upper end of the range, while low temperature from a heat pump achieves the lower end. We determine the number and size of the units upon request based on the heating load and water temperature of your hall. Range of application: according to the page, medium and large rooms: industrial halls, workshops, warehouses, pavilions, sports halls, churches; heating water from the boiler.\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 1.4em;line-height:1.6;font-size:0.88em;color:#555555;\"\u003e* The heating capacity of a water-air heater depends on the flow and return temperatures of the heating water, the air inlet temperature and the fan speed; the range stated on the page covers these operating points. The decisive factors for the number and size of the units are the calculated heating load of the hall, not the floor area. The binding design is carried out on an object-specific basis. For the design of your property, \u003ca href=\"https:\/\/warmandcold-shop.de\/pages\/kontakt\" target=\"_blank\" rel=\"noopener\"\u003eplease contact us\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eThe most important advantages at a glance\u003c\/h2\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003e4 sizes from 24.5 to 70.0 kW\u003c\/strong\u003e according to the page (HD25, HD40, HD50, HD70), one page for the entire range.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eHeating water from the existing system:\u003c\/strong\u003e boiler, heat pump or district heating, 3\/4 inch connection.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eThree fan speeds (AC fan)\u003c\/strong\u003e.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eAccessories as an option:\u003c\/strong\u003e CTS, swivel bracket; complete set with hoses and valve with actuator.\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003eHousing:\u003c\/strong\u003e EPP; adjustable air guide louvres according to the page.\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eDetailed functions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHeat exchanger and heating water\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eHeat exchanger: information about the heat exchanger is provided on the page exclusively as an image; available upon request. 3\/4 inch connection (according to the page for hoses and valve of the complete set). The page does not state the maximum water temperature and maximum operating pressure; available upon request. For operation with a heat pump at a low flow temperature, we check the achievable performance upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eFan and air distribution\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThree fan speeds (AC fan). The page does not state the air volume, sound pressure level and throw distance in the text; they are provided there exclusively as an image; we provide the values upon request. The air guide louvres are adjustable according to the page.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eControl and accessories\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eCTS: 3-speed rotary controller with thermostat, operating modes heating, ventilation or thermostat operation (at the setpoint temperature, the valve closes and the fan stops; in continuous operation, the fan continues to run). CHMI: programmable control with built-in thermostat, weekly program with 6 time zones, frost protection when switched off, connection to building management systems possible, temperature sensor built-in or as a wall sensor CNTC, plastic housing.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eInstallation\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eSwivel bracket in every set; according to the page, installation on walls in any orientation (horizontal, vertical, angled), the recommended distances to walls must be observed. Installation, hydraulic connection, venting and electrical connection are carried out by a specialist company.\u003c\/p\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eScope of delivery\u003c\/h2\u003e\n\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eDepending on the selected option according to the page:\u003c\/p\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003ewith swivel bracket:\u003c\/strong\u003e air heater and swivel bracket\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003ewith swivel bracket and 3-speed controller with CTS thermostat:\u003c\/strong\u003e air heater, swivel bracket, CTS controller\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003ewith swivel bracket and programmable CHMI control:\u003c\/strong\u003e air heater, swivel bracket, CHMI control\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e\n\n\u003cstrong\u003ecomplete set:\u003c\/strong\u003e air heater, swivel bracket, CTS controller, 2 hoses HC 3\/4 inch, 1 valve 3\/4 inch with actuator\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat you need additionally\u003c\/h3\u003e\n\n\u003cul style=\"margin:0 0 1.2em;padding-left:1.3em;line-height:1.7;\"\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eHeating water supply with flow and return (boiler, heat pump or district heating), piping to the unit, shut-off valves and hoses, unless included in the complete set\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003e230 V electrical supply line, AC motor according to the page with fuse, control cable to the controller\u003c\/li\u003e\n\n  \u003cli style=\"margin-bottom:0.45em;\"\u003eInstallation, hydraulic and electrical connection as well as commissioning by a specialist company\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eTechnical data\u003c\/h2\u003e\n\n\u003ctable style=\"margin:0.5em 0 1.5em;border-collapse:collapse;width:100%;\"\u003e\n\n  \u003ctbody\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHD25\u003c\/td\u003e\n\n\u003ctd\u003eHD40\u003c\/td\u003e\n\n\u003ctd\u003eHD50\u003c\/td\u003e\n\n\u003ctd\u003eHD70\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHeating capacity according to the page\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e24.5 kW\u003c\/td\u003e\n\n\u003ctd\u003e37.8 kW\u003c\/td\u003e\n\n\u003ctd\u003e48.5 kW\u003c\/td\u003e\n\n\u003ctd\u003e70.0 kW\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAir volume\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eSound pressure level\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eThrow distance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHeating water connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\/4 inch (according to the page for hoses and valve of the complete set)\u003c\/td\u003e\n\n\u003ctd\u003e3\/4 inch (according to the page for hoses and valve of the complete set)\u003c\/td\u003e\n\n\u003ctd\u003e3\/4 inch (according to the page for hoses and valve of the complete set)\u003c\/td\u003e\n\n\u003ctd\u003e3\/4 inch (according to the page for hoses and valve of the complete set)\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. medium temperature \/ operating pressure\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e230 V, AC motor according to the page\u003c\/td\u003e\n\n\u003ctd\u003e230 V, AC motor according to the page\u003c\/td\u003e\n\n\u003ctd\u003e230 V, AC motor according to the page\u003c\/td\u003e\n\n\u003ctd\u003e230 V, AC motor according to the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\u003ctd\u003enot stated on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eEPP according to the page\u003c\/td\u003e\n\n\u003ctd\u003eEPP according to the page\u003c\/td\u003e\n\n\u003ctd\u003eEPP according to the page\u003c\/td\u003e\n\n\u003ctd\u003eEPP according to the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n    \u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eManufacturer according to the page\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003enot mentioned on the page\u003c\/td\u003e\n\n\u003ctd\u003enot mentioned on the page\u003c\/td\u003e\n\n\u003ctd\u003enot mentioned on the page\u003c\/td\u003e\n\n\u003ctd\u003enot mentioned on the page\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n  \u003c\/tbody\u003e\n\n\n\u003c\/table\u003e\n\n\u003ch2 style=\"margin:2.0em 0 0.6em;line-height:1.35;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhich size of the Trinnity HD is suitable for my hall?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe decisive factors are the heating load and water temperature, not the square meters: The page states 24.5 kW to 70.0 kW for the 4 sizes, but this is only achieved with correspondingly warm heating water. For large halls, several units distribute the heat better than a single one. We determine the units upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat water temperature does the air heater need?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe limits for water temperature and pressure are not stated on the page; available upon request. The warmer the water, the more performance: boiler temperatures achieve the upper end of the range, heat pump temperatures the lower. We calculate what value is achieved at your flow upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhat is included in the individual options?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eAccording to the page: with swivel bracket: air heater and swivel bracket; with swivel bracket and 3-speed controller with CTS thermostat: air heater, swivel bracket, CTS controller; with swivel bracket and programmable CHMI control: air heater, swivel bracket, CHMI control; complete set: air heater, swivel bracket, CTS controller, 2 hoses HC 3\/4 inch, 1 valve 3\/4 inch with actuator. Piping, shut-off valves outside the complete set, electrical supply line and installation material are not included.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow is the air heater controlled?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eVia the accessories on this page: CTS: 3-speed rotary controller with thermostat, operating modes heating, ventilation or thermostat operation (at the setpoint temperature, the valve closes and the fan stops; in continuous operation, the fan continues to run). CHMI: programmable control with built-in thermostat, weekly program with 6 time zones, frost protection when switched off, connection to building management systems possible, temperature sensor built-in or as a wall sensor CNTC, plastic housing. Without control, the fan is switched externally, automatic temperature maintenance is then not possible.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eHow loud is the unit and how far does the airflow reach?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eThe sound pressure level and throw distance are not stated in the text on the page (the data is provided there exclusively as an image); we provide the values for each fan speed upon request.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I connect the air heater to a heat pump?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eYes, to any heating water source with flow and return, so also to a heat pump. At a low flow temperature, the performance drops significantly; we calculate upon request whether the size and number of units then still fit the heating load.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eWhere is the unit mounted?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eSwivel bracket in every set; according to the page, installation on walls in any orientation (horizontal, vertical, angled), the recommended distances to walls must be observed. The airflow should point towards the living area, without blowing directly on people; the throw distance helps in choosing the installation location.\u003c\/p\u003e\n\n\u003ch3 style=\"margin:1.5em 0 0.45em;line-height:1.35;\"\u003eCan I install and connect the air heater myself?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 0.95em;line-height:1.7;\"\u003eNo. Installation, hydraulic connection with venting, electrical connection and commissioning are carried out by a specialist company; this also applies to the connection of the controller and a valve with an actuator.\u003c\/p\u003e\n\n\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Welche Größe des Trinnity HD passt zu meiner Halle?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Entscheidend sind Heizlast und Wassertemperatur, nicht die Quadratmeter: Die Seite nennt für die 4 Größen 24,5 kW bis 70,0 kW, erreicht wird das erst mit entsprechend warmem Heizwasser. Für große Hallen verteilen mehrere Geräte die Wärme besser als ein einzelnes. Wir legen die Geräte auf Anfrage aus.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Welche Wassertemperatur braucht der Lufterhitzer?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Grenzwerte für Wassertemperatur und Druck stehen nicht auf der Seite; Angabe auf Anfrage. Je wärmer das Wasser, desto mehr Leistung: Kesseltemperaturen bringen das obere Ende der Spanne, Wärmepumpentemperaturen das untere. Welcher Wert bei Ihrem Vorlauf erreicht wird, rechnen wir auf Anfrage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Was ist in den einzelnen Varianten enthalten?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laut Seite: mit Drehkonsole: Lufterhitzer und Drehkonsole; mit Drehkonsole und 3-stufigem Drehzahlregler mit Thermostat CTS: Lufterhitzer, Drehkonsole, Regler CTS; mit Drehkonsole und programmierbarer CHMI-Steuerung: Lufterhitzer, Drehkonsole, CHMI-Steuerung; Komplettset: Lufterhitzer, Drehkonsole, Regler CTS, 2 Schläuche HC 3\/4 Zoll, 1 Ventil 3\/4 Zoll mit Stellmotor. Rohrleitungen, Absperrventile außerhalb des Komplettsets, Elektrozuleitung und Montagematerial gehören nicht dazu.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie wird der Lufterhitzer gesteuert?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Über das Zubehör dieser Seite: CTS: 3-stufiger Drehregler mit Thermostat, Betriebsarten Heizen, Lüften oder Thermostatbetrieb (bei Solltemperatur schließt das Ventil und der Lüfter stoppt; im Dauerbetrieb läuft der Lüfter weiter). CHMI: programmierbare Steuerung mit eingebautem Thermostat, Wochenprogramm mit 6 Zeitzonen, Frostschutz im ausgeschalteten Zustand, Anbindung an eine Gebäudeleittechnik möglich, Temperaturfühler eingebaut oder als Wandfühler CNTC, Kunststoffgehäuse. Ohne Steuerung wird der Ventilator bauseits geschaltet, eine automatische Temperaturhaltung ist dann nicht möglich.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wie laut ist das Gerät und wie weit reicht der Luftstrom?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Schalldruckpegel und Wurfweite nennt die Seite nicht im Text (die Daten stehen dort ausschließlich als Bild); wir reichen die Werte je Lüfterstufe auf Anfrage nach.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Kann ich den Lufterhitzer an eine Wärmepumpe anschließen?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Ja, an jede Heizwasserquelle mit Vor- und Rücklauf, also auch an eine Wärmepumpe. Bei niedriger Vorlauftemperatur sinkt die Leistung spürbar; wir rechnen auf Anfrage, ob Größe und Anzahl der Geräte dann noch zur Heizlast passen.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Wo wird das Gerät montiert?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Drehkonsole in jedem Set; laut Seite Montage an Wänden in jeder Lage (waagerecht, senkrecht, schräg), empfohlene Abstände zu Wänden sind einzuhalten. Der Luftstrom sollte auf den Aufenthaltsbereich zeigen, ohne direkt auf Personen zu blasen; die Wurfweite hilft bei der Wahl des Montageorts.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Darf ich den Lufterhitzer selbst montieren und anschließen?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Nein. Montage, hydraulischer Anschluss mit Entlüftung, elektrischer Anschluss und Inbetriebnahme übernimmt ein Fachbetrieb; das gilt auch für den Anschluss des Reglers und eines Ventils mit Stellmotor.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Trinnity","offers":[{"title":"HD25 24.5 kW \/ + Rotating console","offer_id":41048788795544,"sku":"","price":399.0,"currency_code":"EUR","in_stock":false},{"title":"HD25 24.5 kW \/ + Rotating console + 3-stage speed controller with thermostat","offer_id":41048788828312,"sku":"","price":414.0,"currency_code":"EUR","in_stock":false},{"title":"HD25 24.5 kW \/ + Rotating console + programmable CHMI control","offer_id":41048788861080,"sku":"","price":468.0,"currency_code":"EUR","in_stock":false},{"title":"HD25 24.5 kW \/ + Rotating console + 3-stage speed controller with thermostat + 2 pcs. hoses HC 3\/4\" + 1 pc. valve 3\/4\" servo motor","offer_id":41048788893848,"sku":"","price":547.0,"currency_code":"EUR","in_stock":false},{"title":"HD40 37.8 kW \/ + Rotating console","offer_id":41048788926616,"sku":"","price":419.0,"currency_code":"EUR","in_stock":false},{"title":"HD40 37.8 kW \/ + Rotating console + 3-stage speed controller with thermostat","offer_id":41048788959384,"sku":"","price":434.0,"currency_code":"EUR","in_stock":false},{"title":"HD40 37.8 kW \/ + Rotating console + programmable CHMI control","offer_id":41048788992152,"sku":"","price":498.0,"currency_code":"EUR","in_stock":false},{"title":"HD40 37.8 kW \/ + Rotating console + 3-stage speed controller with thermostat + 2 pcs. hoses HC 3\/4\" + 1 pc. valve 3\/4\" servo motor","offer_id":41048789024920,"sku":"","price":567.0,"currency_code":"EUR","in_stock":false},{"title":"HD50 48.5 kW \/ + Rotating console","offer_id":41048789057688,"sku":"","price":459.0,"currency_code":"EUR","in_stock":false},{"title":"HD50 48.5 kW \/ + Rotating console + 3-stage speed controller with thermostat","offer_id":41048789090456,"sku":"","price":484.0,"currency_code":"EUR","in_stock":false},{"title":"HD50 48.5 kW \/ + Rotating console + programmable CHMI control","offer_id":41048789123224,"sku":"","price":538.0,"currency_code":"EUR","in_stock":false},{"title":"HD50 48.5 kW \/ + Rotating console + 3-stage speed controller with thermostat + 2 pcs. hoses HC 3\/4\" + 1 pc. valve 3\/4\" servo motor","offer_id":41048789155992,"sku":"","price":617.0,"currency_code":"EUR","in_stock":false},{"title":"HD70 70 kW \/ + Rotating console","offer_id":41048789188760,"sku":"","price":639.0,"currency_code":"EUR","in_stock":false},{"title":"HD70 70 kW \/ + Rotating console + 3-stage speed controller with thermostat","offer_id":41048789221528,"sku":"","price":664.0,"currency_code":"EUR","in_stock":false},{"title":"HD70 70 kW \/ + Rotating console + programmable CHMI control","offer_id":41048789254296,"sku":"","price":718.0,"currency_code":"EUR","in_stock":false},{"title":"HD70 70 kW \/ + Rotating console + 3-stage speed controller with thermostat + 2 pcs. hoses HC 3\/4\" + 1 pc. valve 3\/4\" servo motor","offer_id":41048789287064,"sku":"","price":797.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0488\/7029\/3656\/products\/3-0.jpg?v=1633007246","url":"https:\/\/warmandcold-shop.de\/en\/products\/trinnity-hd-lufterhitzer-24-5-bis-70-kw-hallenheizung","provider":"warm\u0026cold","version":"1.0","type":"link"}